UWS Umweltmanagement GmbH Frame öffnen


Tabelle 1: intratracheale Halbwertzeiten für WHO-Fasern und Fasern mit L > 20 µm von Fasernsuspensionen nach (7); Angaben in Tagen;

Tabelle 1

intratracheal, WHO

intratracheal L > 20 µm
Nr. Fasertyp K1 T1-WHO (VB) T2-WHO (VB) TW-WHO (VB) T1-20 (VB) T2-20 (VB) TW-20 (VB)
1 MMVF-Ba
= Exp 44
43 164 (137-191) - - 92 (83-101) - -
2 MMVF-M 40 14 (12-17)
1 (0-2)
-
17 (13-21)
-
8 (4-13)
8 (6-11)
6 (4-7)
- -
3 MMVF-O 40 25 (20-31)
16 (14-18)
- - 11 (10-12) 12 (11-14) - -
4 B01/09 39 18 (13-23) - - 5 (3-8) - -
5 X-607 37 45 (36-55) - - 3 (-2-7) 36 (25-47) 13 (5-21)
6 MMVF-C 34 27 (23-31)
21 (18-23)
-
-
-
-
12 (9-15)
10 (8-12)
-
-
-
-
7 MMVF-CS 34 40 (34-45) - - 22 (18-26) - -
8 MMVF-P 33 13 (5-22) 61 (-91-212) 22 (12-32) 12 (10-14) - -
9 MMVF-G 32 64 (44-85)
4 (2-6)
7 (4-11)
48 (7-90)
18 (13-22)
12 (9-16)
5 (4-7)
2 (2-3)
79 (58-100)
41 (21-61)
17 (14-20)
7 (5-8)
10 MMVF-22 28 77 (71-83) - - 44 (3 8-50) - -
11 G-TL 25 134 (105-163)
6 (-2-13)
-
223(-30-475)
-
117(5-230)
38 (35-41)
107 (53-160)
-

-

-

-

12 MMVF-11 24 155 (132-178) - - 39 (19-60) 137 (65-209) 61 (51-71)
13 M-S(tone) 15 122 (117-126) - - 78 (70-86) - -
14 MMVF-21 4 276 (201-351) - - 184 (150-217) - -
15 MMVF 34 = HT 7 -17 60 (53-65) - - 70 (65-74) - -
16 Exp 50 = HT3 -48 114 (105-123) - - 112 (97-127) - -
17 RCF-1 -95 296 (245-347) - - 233 (193-273) - -
18 MMVF-R Keramik? -95 1046
(-1182-3275)
- - 658
(-250-1567)
- -

VB: 95 % Vertrauensbereich

T1: Haibwertzeit beim Vorliegen einer einphasigen Eilminationskinetik bzw. Haibwertzeit der schnellen Eliminationsphase beim Vorliegen einer biphasigen Eliminationskineti

T2: Halbwertszeit der langsamen Eliminationsphase beim Vorliegen einer biphasigen Eliminationskineti

TW: gewichtete Halbwertszeit beim Vorliegen einer biphasigen Elminationskinetik

Tabelle 2: inhalative Halbwertzeiten für WHO-Fasern und Fasern mit L > 20 µm von Fasernsuspensionen nach (7); Angaben in Tagen; VB: 95 % Vertrauensbereich


inhalativ, WHO

inhalativ L >20 µm

Nr. Fasertyp K1 T1-WHO (VB) T2-WHO (VB) TW-WHO (VB) T1-20 (VB) T2-20 (VB) TW-20 (VB)
1 MMVF-M 40 12 (10-13) - 5 (4-7) - -
2 MMVF-O 40 17 (15-18) - - 6 (5-7) - -
3 BO1/09 39 5 (4-14) 71 (-120-260) 13 (4-30) 2 (14) 36 (-37-109) 2 (1-4)
4 X-607 37 5 (2-7) 125 (42-208) 23 (13-33) 4(2-6) 94 (28-160) 10 (6-14)
5 MMVF-C 34 2 (-1-5) 46 (35-56) 14 (8-21) 5 (4-6) - -
6 MMVF-P 33 18 (15-21) - 6 (5-6) - -
7 MMVF-G 32 7 (0-14) 68 (33-102) 22 (17-27) 6 (5-7) - -
8 MMVF-F 30 12 (13-36) 71 (-2-143) 28 (17-38) 9 (6-12) - -
9 MMVF-H 28 5 (1-10) 75 (38-112) 26(17-34) 7 (2-12) 59 (16-102) 16 (10-22)
10 MMVF-22 28 62(5668) - - 2 (-1-4) 30 (-13-72) 8 (1-16)
11 MMVF-A 28 2 (0-4) 49 (34-64) 13 (?) 2 (1-3) 26 (1438) 3 (2-5)
12 MMVF- PR141 27 38 (35-41) - - 18 (17-19) - -
13 MMVF-10 27 56 (15-96) 305 (-918-1529) 90 (31-151) 24 (-4-53) 85 (-13-184) 35 (22-49)
14 MMVF-11 24 13 (-5-31)

31 (6-55)

61 (15-108) 172 (-27-372) 28 (17-39)
59 (38-80)
9 (3-15)

3 (1-5)

48 (7-88)

36 (19-54)

13 (7-18)

9 (4-13)

15 MMVF33

= 475

19 18 (13-21) 178 (145-210) 70 (62-78) 4 (2-6) 140 (116-163) 48 (32-63)
16 MMVF-21 4 4 (-5-13)

6 (2-10)

85 (75-96)

92 (62-123)

110 (96-125)

-

42 (7-77)

65 (50-80)

-

6 (-4-16)

92 (78-107) 38 (18-58)

55 (43-66)

-

725 (-4362-5812)

35 (20-50)

-

98 (-240-436)

17 MMVF 32

= E

3 6 (4-9) 160 (134-185) 63 (50-77) 6 (3-8) 180 (146-214) 68 (48-89)
18 MMVF-L -3 6 (0-11) 78 (42-115) 32 (20-43) 6 (-7-19) 60(33-86) 35 (20-50)
19 MMVF 34

= HT 7

-17 6 (5-8) 53 (49-57) 22 (19-25) 5 (4-6) -- -
20 RCF-1 -95 6 (3-8) 104 (95-115) 54 (43-65) 5 (3-7) 87 (80-94) 41 (32-51)
21 Amosit - 71 (44-98) - - 17 (10-23) 1300 (-800-3500) 466 (-300-1160)

T1: Halbwertzeit beim Vorliegen einer einphasigen Eliminationskinetik bzw. Halbwertzeit der schnellen Eliminationsphase beim Vorliegen einer biphasigen Eliminationskinetik

T2: Halbwertszeit der langsamen Eliminationsphase beim Vorliegen einer biphasigen Eliminationskinetik

TW: gewichtete Halbwertszeit beim Vorliegen einer biphasigen Eliminationskinetik

UWS Umweltmanagement GmbH Frame öffnen